User GuideVersion 3.5Verilink Corporation127 Jetplex CircleMadison, Alabama 35758http://www.verilink.comCopyright 2003 Polycom, Inc. All rights reserv
. - x - NetEngine IAD User Guideset dhcp server netbios ...247set dhcp server domain ...
NetEngine IAD User GuideWAN Configuration 81Configuring ATM PVCsYou may configure up to 8 ATM PVCs on the IAD. To configure create and manage PVCs, ty
NetEngine IAD User GuideWAN Configuration 824. The IAD displays the ATM Encapsulation Configuration menu.Figure 4–37. ATM Encapsulation Configuration
NetEngine IAD User GuideWAN Configuration 83Type the value for the peak cell rate.7. The IAD saves the configuration and displays the PVC Configuratio
NetEngine IAD User GuideWAN Configuration 84Setting up AAL5 or AAL0 Encapsulation1. Type 1 to select AAL5, or type 2 to select AAL0 encapsulation. 2.
NetEngine IAD User GuideWAN Configuration 85Figure 4–43. ATM Encapsulation Configuration Menu To select CBR, type 1. To select UBR, type 2.3. The IAD
NetEngine IAD User GuideWAN Configuration 86Figure 4–45. IPCP Configuration Menu Type the option corresponding to the IP address you want to use. 5.
NetEngine IAD User GuideWAN Configuration 87Figure 4–47. ATM PCR Configuration Menu Type the PCR value or press Enter to set the PCR to the maximum r
NetEngine IAD User GuideWAN Configuration 88Type the PCR value or press Enter to set the PCR to the maximum rate for the current line speed.4. The IAD
NetEngine IAD User GuideWAN Configuration 89Deleting a PVCTo delete a PVC:1. Type 3 to select Delete PVC.2. The IAD displays the port list and a promp
NetEngine IAD User GuideWAN Configuration 90ConfiguringATM OptionsTo configure ATM options, type 4 to display the ATM Configuration menu:Figure 4–54.
. - xi - NetEngine IAD User GuideChapter 14 Troubleshooting and DiagnosticsUsing the Diagnostics Menu...
NetEngine IAD User GuideWAN Configuration 91This value must match one of the WAN PVCs. For more information, see Configuring ATM PVCs on page 81. 2. T
NetEngine IAD User GuideWAN Configuration 924. Press any key to display the ATM Configuration menu.Configuring EmptyCells1. On the ATM Configuration m
NetEngine IAD User GuideWAN Configuration 93ConfiguringFrame Relay DLCIsTo configure Frame Relay DLCIs, type 3 on the WAN Configuration menu. The IAD
NetEngine IAD User GuideWAN Configuration 94Adding a DLCITo add a DLCI:1. On the Frame Relay DLCI Configuration menu, type 1 to select Add New DLCI.2.
NetEngine IAD User GuideWAN Configuration 956. The IAD displays the throughput prompt:Enter the Circuit Throughput in bits/second (2048000): Type the
NetEngine IAD User GuideWAN Configuration 9616. If you type 2, the IAD displays the fragment size prompt:Enter maximum fragment size in bytes (100-160
NetEngine IAD User GuideWAN Configuration 97ConfiguringFrame Relay OptionsTo configure Frame Relay options, type 4 on the WAN Configuration menu. The
NetEngine IAD User GuideWAN Configuration 98Figure 4–62. FRF.12 Configuration Menu Type the option and proceed to the corresponding section.Enabling
NetEngine IAD User GuideWAN Configuration 99Figure 4–63. FRF.12 Configuration Menu for CopperMountain Type the option and proceed to the correspondin
NetEngine IAD User GuideWAN Configuration 100Figure 4–64. Frame Relay Maintenance Protocol Menu 4. Type the number that corresponds to the protocol o
NetEngine IAD User GuideThe Verilink NetEngine Family IAD User Guide contains the information you need to install, connect and configure each Verilink
NetEngine IAD User GuideWAN Configuration 101Enabling or Disabling Coppermountain CMCPTo enable or disable Coppermountain CMCP:1. On the Main menu, se
NetEngine IAD User GuideWAN Configuration 102Quick Con-figurationThe 6300 contains a number of predefined configurations for physical connections and
NetEngine IAD User GuideThis chapter describes how to configure the IAD as a router. You may configure the IAD as a router or a bridge, depending on y
NetEngine IAD User GuideRouter Configuration 104Basic Router Setup TasksTo configure the IAD as a router, you should complete the following tasks:Conf
NetEngine IAD User GuideRouter Configuration 105Router Configur-ation MenuRouter tasks are all displayed and accessed on the Router Configuration menu
NetEngine IAD User GuideRouter Configuration 106Configuringa Port IP AddressTo configure the IAD as a router, you must assign an IP address to both th
NetEngine IAD User GuideRouter Configuration 1078. Configuration is complete. The IAD displays the following prompt:Save new IP Information?->(Y)Ty
NetEngine IAD User GuideRouter Configuration 108Unconfig-uring a Port IP AddressTo unconfigure (delete) the IP address of an interface, follow these s
NetEngine IAD User GuideRouter Configuration 109Setting the Port Maximum Transmis-sion UnitThe MTU setting controls IP fragmentation of packets transm
NetEngine IAD User GuideRouter Configuration 110Enabling and Disabling RIPWhen you enable RIP, the IAD sends routing data to adjacent routers and dyna
NetEngine IAD User GuidePreface xivChapter 7, Voice Path Configuration on page 139, describes how to set up voice ports for use in various DSLAM and v
NetEngine IAD User GuideRouter Configuration 111Setting the RIP VersionTo set the RIP version:1. Type V on the Router Configuration menu to select Con
NetEngine IAD User GuideRouter Configuration 112Managing Static and Default RoutesTo create, update and delete static and default routes, type S on th
NetEngine IAD User GuideRouter Configuration 113Removing a Static RouteTo delete a static route from the Route Table:1. On the Router Modification men
NetEngine IAD User GuideRouter Configuration 114Config-uring DNS ClientDNS Client allows the IAD to use fully-qualified domain names; for example, www
NetEngine IAD User GuideRouter Configuration 115Displaying the DNS Cache and StatisticsTo display information about the data in the DNS cache, type S.
NetEngine IAD User GuideRouter Configuration 116Config-uring DHCP ClientTo enable or disable DHCP Client on an interface, follow these steps:1. Type H
NetEngine IAD User GuideRouter Configuration 117Config-uring DHCP RelayDHCP Relay allows the IAD to forward DHCP requests from the LAN to a separate D
NetEngine IAD User GuideRouter Configuration 1184. Continue with other configuration tasks, or press Escape to return to the Router Modification menu.
NetEngine IAD User GuideRouter Configuration 119Configur-ing the Telnet Server PortWhen using NAT on the IAD, it is often desired to configure a host
NetEngine IAD User GuideRouter Configuration 120Each of the tasks in this section originate at the IP Filtering Configuration menu. Type the option fo
NetEngine IAD User GuidePreface xvDo not spray liquids directly onto the system when cleaning. Always apply the liquid first to a static free cloth. D
NetEngine IAD User GuideRouter Configuration 1213. The IAD enables or disables input filters, and displays the status of the output filters, with anot
NetEngine IAD User GuideRouter Configuration 1222. Follow the IAD messages to enter values for the following parameters: 3. When you enter the last pa
NetEngine IAD User GuideRouter Configuration 123Copying a FilterTo copy a filter to the filter buffer for viewing or editing, follow these steps:1. On
NetEngine IAD User GuideRouter Configuration 124Editing a Filter in the BufferTo edit a filter currently stored in the buffer, follow these steps:1. O
NetEngine IAD User GuideRouter Configuration 125Deleting All Filters of the Chosen TypeTo delete all filters from the IP Filter table, toggle input or
NetEngine IAD User GuideRouter Configuration 126Config-uring IP Header Compress-ion (IPHC)IPHC reduces the number of bytes transmitted across the WAN,
NetEngine IAD User GuideRouter Configuration 127Config-uring the LAN IP Broadcast DestinationTo set the LAN IP broadcast destination address (where al
NetEngine IAD User GuideRouter Configuration 128
NetEngine IAD User GuideThis chapter describes how to configure the IAD as a bridge. A bridge is a device that connects and passes packets between two
NetEngine IAD User GuideBridge Configuration 130Basic Bridge Setup TasksAlthough the IAD is pre-configured with bridging enabled, you should perform t
NetEngine IAD User GuidePreface xviRegulatory NoticesFCC NoticeAll NetEngine products except the NE6100-4 have been tested and found to comply with th
NetEngine IAD User GuideBridge Configuration 131Bridge Configur-ation MenuConfiguring the IAD as a bridge involves several tasks. These are all displa
NetEngine IAD User GuideBridge Configuration 132Enabling and Disabling BridgingFor bridging to function correctly, you must enable bridging both globa
NetEngine IAD User GuideBridge Configuration 133Bridging is globally DISABLEDEnter E to Enable, D to Disable:Type E to enable bridging globally, or D
NetEngine IAD User GuideBridge Configuration 134Setting the Bridge Aging TimerThe bridge aging timer establishes the amount of time that the IAD keeps
NetEngine IAD User GuideBridge Configuration 1351. G2237 xDSL2. 10/100BaseT Ethernet0. (Abort)Type the number of the port for which you want to enable
NetEngine IAD User GuideBridge Configuration 1363. If more than one interface is configured on the selected port, the IAD displays a list of interface
NetEngine IAD User GuideBridge Configuration 137Config-uring Spanning Tree Forward DelayTo set the Spanning Tree forward delay (a value between 4-30 s
NetEngine IAD User GuideBridge Configuration 138Deleting a Bridge Forwarding Database EntryTo delete an Ethernet address from the bridge forwarding da
NetEngine IAD User GuideAfter you have defined the voice PVCs or DLCIs on the IAD, you should configure the voice path for voice operation to function
NetEngine IAD User GuideVoice Path Configuration 140Basic Voice Path Setup TasksTo configure voice path settings, you should complete the following ta
NetEngine IAD User GuidePreface xviiBefore connecting your IAD, you must inform the telephone company of the following information. An FCC compliant t
NetEngine IAD User GuideVoice Path Configuration 141Setting the Voice GatewayTo select a voice gateway:1. Type V on the Voice Configuration menu to se
NetEngine IAD User GuideVoice Path Configuration 1424. Reset the IAD (page 15) when you finish voice path configuration.When you choose a specific voi
NetEngine IAD User GuideVoice Path Configuration 143Displaying Jitter DelayTo display the current jitter delay value, type D on the Voice Configuratio
NetEngine IAD User GuideVoice Path Configuration 144Configuring Start Mode on an Individual Port1. Type 4 on the Start Mode Selection menu to select C
NetEngine IAD User GuideVoice Path Configuration 145Setting Compander ModeTo set Compander Mode, type U to display the Compander Mode Selection menu:F
NetEngine IAD User GuideVoice Path Configuration 146Setting Idle Voltage ModeTo set idle high voltage for loop start lines (POTS only), type L to disp
NetEngine IAD User GuideVoice Path Configuration 147Setting Debug ModeOption M, Set Debug Mode, is reserved for Verilink network engineers.Configur-in
NetEngine IAD User GuideVoice Path Configuration 148Setting Loop GainIf the IAD feeds telephone circuits into a legacy PBX or other equipment that def
NetEngine IAD User GuideVoice Path Configuration 149Displaying Loop Gain SettingsTo display information about Loop Gain settings, type 2. The IAD disp
NetEngine IAD User GuideVoice Path Configuration 150Setting Country ModeThe country mode selection menu allows you to select a national parameter list
NetEngine IAD User GuidePreface xviiiappropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipmen
NetEngine IAD User GuideVoice Path Configuration 151Managing MGCP Embedded ClientThis section applies to MGCP—Voice Over IP—gateway management.To conf
NetEngine IAD User GuideVoice Path Configuration 152Available Interfaces:1. G2237 xDSL2. 10/100BaseT Ethernet0. (Abort)Selection:Type the option numbe
NetEngine IAD User GuideVoice Path Configuration 153Port AdministrationType A to display the Port Administration menu:Figure 7–13. Port Administratio
NetEngine IAD User GuideVoice Path Configuration 154Restarting an EndpointType 4 to reset the connection between the Voice Port phone and the MGCP voi
NetEngine IAD User GuideVoice Path Configuration 155Managing Copper-Com Call ControlWhen your IAD is configured for connection to a Coppercom Voice Ga
NetEngine IAD User GuideVoice Path Configuration 156Figure 7–16. CopperCom Configuration Menu Type the option for the command to execute and proceed
NetEngine IAD User GuideVoice Path Configuration 157Type 1 to select a 36 octet packet, using a single packet per frame, or type 2 to select a 44 octe
NetEngine IAD User GuideVoice Path Configuration 158JetStream Call Control SettingsWhen you have specified the JetStream Voice Gateway, type E to disp
NetEngine IAD User GuideVoice Path Configuration 159Configuring the Ring TestType C to configure the ring test.1. The IAD displays the port prompt:Por
NetEngine IAD User GuideVoice Path Configuration 160Figure 7–20. Ring Test Menu for JetStream Voice Gateway Type 0 to replace the dial tone with sile
NetEngine IAD User GuidePreface xixKonformitetserklæring:Hermed erklærer Polyspan Ltd., at indestående NetEngine er i overensstemmelse med de grundlæg
NetEngine IAD User GuideVoice Path Configuration 161Configur-ing AAL2/LES CASATM Adaptation Layer 2/Loop Emulation Services (AAL2/LES) is a broadband
NetEngine IAD User GuideVoice Path Configuration 162settings is a message indicating the IAD will be configured for the selected gateway after reset.3
NetEngine IAD User GuideVoice Path Configuration 1634. Reset the IAD (page 15) when you finish voice path configuration.Changing the Maximum CPS-SDU S
NetEngine IAD User GuideVoice Path Configuration 164Manual ATM pace control (disabled) [E/D]:3. Type E to enable pace control, or D to disable pace co
NetEngine IAD User GuideVoice Path Configuration 165Configur-ing AAL2/LES CCS-ELCPATM Adaptation Layer 2/Loop Emulation Services (AAL2/LES) is a broad
NetEngine IAD User GuideVoice Path Configuration 166Debugging for AAL2/LES CCS-ELCPType D to display the Debugging menu:Figure 7–29. AAL2/LES CCS-ELC
NetEngine IAD User GuideVoice Path Configuration 167Displaying AAL2 Channel StatisticsType D to display the AAL2 channel statistics:<<< Audio
NetEngine IAD User GuideVoice Path Configuration 168
NetEngine IAD User GuideCreating a Firewall via IP FilteringFirewall configuration (also known as IP filtering) allows you to specify a combination of
NetEngine IAD User GuideFirewall Configuration 170
NetEngine IAD User GuidePreface xx
NetEngine IAD User GuideThis chapter describes the tasks required to configure the Dynamic Host Configuration Protocol (DHCP) server on the LAN connec
NetEngine IAD User GuideDHCP Server Configuration 172Basic DHCP Server Setup TasksWhen DHCP is enabled, it dynamically assigns an IP address to each d
NetEngine IAD User GuideDHCP Server Configuration 173Using DHCP Debugging MessagesThe commands in option B, Enable/Disable DHCP Debug Messages, are re
NetEngine IAD User GuideDHCP Server Configuration 174Configur-ing DHCP Server ParametersTo configure DHCP Server parameters, type I on the DHCP Server
NetEngine IAD User GuideDHCP Server Configuration 175Configuringthe DHCP Address Range PoolYou must configure the DHCP address range pool to set the r
NetEngine IAD User GuideDHCP Server Configuration 176Enter Y to enter a value for Subnet MaskEnter N to use a default valueCurrent Subnet Mask = 0.0.0
NetEngine IAD User GuideDHCP Server Configuration 177Displaying DHCP Server Details13. Type F to display the current configuration of the DHCP Server:
NetEngine IAD User GuideDHCP Server Configuration 178Displaying DHCP Server Statistics Type S to display DHCP Server statistics. The IAD displays the
NetEngine IAD User GuideDHCP Server Configuration 179Displaying DHCP Entry DetailsType D to display DHCP entry details. The IAD displays the following
NetEngine IAD User GuideDHCP Server Configuration 180
NetEngine IAD User GuideThis chapter introduces Verilink’s NetEngine 6000 and 7000 family Integrated Access Devices (IAD) and describes their hardware
NetEngine IAD User GuideMulticast (point-to-multipoint) is a communication feature that allows a source host to send a message to a group of destinati
NetEngine IAD User GuideMulticast Configuration 182Configur-ing MulticastType M to display the Multicast Configuration menu: Figure 10–1. Multicast C
NetEngine IAD User GuideMulticast Configuration 183Configur-ing PIM—Dense Mode by PortType P to configure Protocol-Independent Multicast (PIM) version
NetEngine IAD User GuideMulticast Configuration 184Adding a Multicast Routing SourceType A to add a Multicast Routing Source. The IAD creates a multic
NetEngine IAD User GuideMulticast Configuration 185Removing a Multicast Routing SourceType R to remove a Multicast Routing Source:1. The IAD displays
NetEngine IAD User GuideMulticast Configuration 186Displaying the IGMP GroupIGMP is a communication protocol that operates between a router (The IAD)
NetEngine IAD User GuideMulticast Configuration 187Since Multicast packets are forwarded according to the preceding information, this table is the key
NetEngine IAD User GuideMulticast Configuration 188
NetEngine IAD User GuideThis chapter describes the steps required to configure Network Address Translation (NAT).NAT multiplexes traffic from the inte
NetEngine IAD User GuideNAT Configuration 190The NAT ConfigurationMenuEnabling and managing NAT involves several tasks. These are all displayed and ac
NetEngine IAD User GuideIntroduction 2Data InterfacesThe data connection through the IAD supports IEEE 802.10-compliant bridging and routing.When the
NetEngine IAD User GuideNAT Configuration 191A significant advantage of NAT is that you can configure it without changing hosts or routers, other than
NetEngine IAD User GuideNAT Configuration 192ConfiguringNAT Local ServerTo configure the NAT local server entry, follow these steps:1. Type N on the N
NetEngine IAD User GuideNAT Configuration 19310. The IAD displays this port report:Updating NAT Local Server entry 1, Translated IP address 91.1.1.200
NetEngine IAD User GuideNAT Configuration 194Configuringthe NAT Port RangeThe size of the NAT port range defines the number of simultaneous connection
NetEngine IAD User GuideNAT Configuration 195Configuringthe NAT Alias EntryEach NAT alias entry allows a device on the LAN (inside of NAT) to be acces
NetEngine IAD User GuideNAT Configuration 196NAT StatisticsWhen NAT is enabled, you can review statistics gathered as NAT operates. To display NAT sta
NetEngine IAD User GuideNAT Configuration 197NAT Connection TableWhen NAT is enabled, you can display the current open connections. To display the con
NetEngine IAD User GuideNAT Configuration 198If the connection is not open, the IAD advises you. Press any key to return to the NAT Configuration menu
NetEngine IAD User GuideNAT Configuration 199NAT Local Server TableWhen NAT is enabled, you can display the entries in the local server table. To disp
NetEngine IAD User GuideNAT Configuration 200Deleting a NAT Local Server EntryTo delete a local server entry:1. Type Y on the NAT Configuration menu.
NetEngine IAD User GuideIntroduction 3NetEngine 6500 IADs—provides voice services and high-speed Internet or corporate connectivity over G.SHDSL, and
NetEngine IAD User GuideThis chapter describes the report subsystem in the IAD. The report subsystem allows you to display information about the curre
NetEngine IAD User GuideIAD Reports 202The Report MenuTo display the Reports menu, type 1 on the Main menu.Figure 12–1. Reports MenuMost options on t
NetEngine IAD User GuideIAD Reports 203Current Configur-ation ReportTo display the Current Configuration report, enter C on the Reports menu. The Curr
NetEngine IAD User GuideIAD Reports 204WAN DataLink Protocol Totally Transparent | Raw HDLC | Cisco compatible HDLC | IP-Plus compatible HDLC | PPP (o
NetEngine IAD User GuideIAD Reports 205Sa8 Bit set | clearedRcv Clk Source Internal | ExternalPPP Auth Type (WAN port) None | PAP Client | PAP Server
NetEngine IAD User GuideIAD Reports 206Network Statistics ReportsThe Network Statistics menu contains commands to display statistical information abou
NetEngine IAD User GuideIAD Reports 207discarded for other reasons: - unrecognized codes - bad checksum - packets smaller than header - redirects from
NetEngine IAD User GuideIAD Reports 208IGMP Statistics ReportTo display the IGMP Statistics report, type G on the Network Statistics menu. The IGMP St
NetEngine IAD User GuideIAD Reports 209IP Statistics ReportTo display the IP Statistics report, type I on the Network Statistics menu. The IP Statisti
NetEngine IAD User GuideIAD Reports 210discarded for lack of resourcesDiscarded received packets due to lack of resources: kernel memory, packet buffe
NetEngine IAD User GuideIntroduction 4Rear Panel ConnectorsOn the rear panel (Figure 1–3), the IAD contains several connectors. The type and position
NetEngine IAD User GuideIAD Reports 211PIM Statistics ReportTo display the PIM Statistics report, type P on the Network Statistics menu. The PIM Stati
NetEngine IAD User GuideIAD Reports 212TCP Statistics ReportTo display the TCP Statistics report, type T on the Network Statistics menu. The TCP Stati
NetEngine IAD User GuideIAD Reports 213UDP Statistics ReportTo display the UDP Statistics report, type U on the Network Statistics menu. The UDP Stati
NetEngine IAD User GuideIAD Reports 214Clearing Network StatisticsTo clear network statistics, type Z on the Network Statistics menu. The IAD displays
NetEngine IAD User GuideIAD Reports 215Interface Statistics ReportsType I on the Reports menu to display interface statistics reports. The Interface S
NetEngine IAD User GuideIAD Reports 216ARP Statistics Report To display the ARP Statistics report, type A on the Interface Statistics menu. The ARP St
NetEngine IAD User GuideIAD Reports 217Interface Statistics Report To display the Interface Statistics report, type I on the Interface Statistics menu
NetEngine IAD User GuideIAD Reports 218Bridge Statistics ReportTo display the Bridge Statistics report, type B on the Interface Statistics menu. This
NetEngine IAD User GuideIAD Reports 219Table 12–11.DLCI StatisticsParameter DescriptionCommitted Burst No. of committed info rate (bytes per measureme
NetEngine IAD User GuideIAD Reports 220ATM PVC Statistics ReportTo display the PVC Statistics Reports, type A on the Interface Statistics menu. This o
NetEngine IAD User GuideIntroduction 5NetEngine 7000 IAD FamilyThe Verilink NetEngine 7000 IAD family provides a highly interoperable, cost-effectiv
NetEngine IAD User GuideIAD Reports 221AAL2 Statistics ReportThis PVC Report displays when an AAL2/LES PVC is configured.Table 12–13.Common CPCS-2 Sta
NetEngine IAD User GuideIAD Reports 222Cumulative CPCS-2 Statistics Report Common AAL Statistics ReportThis report displays when ATM protocol is confi
NetEngine IAD User GuideIAD Reports 223Max PDU Max. PDU size limitation for this AAL connection.Rx Frames No. of frames received.Rx Cells No. of AAL c
NetEngine IAD User GuideIAD Reports 224IP Header Compression Statistics ReportThis report is available when ATM PVC Encapsulation Type RFC 1483 is sel
NetEngine IAD User GuideIAD Reports 225PPP Statistics ReportThis report is available when ATM PVC Encapsulation Type RFC 2364 is selected. Clearing In
NetEngine IAD User GuideIAD Reports 226Media Statistics ReportsType M on the Reports menu to display Media statistics reports. Media statistics report
NetEngine IAD User GuideIAD Reports 227Frame Relay Statistics Report Type F to display the Frame Relay Statistics report. This report displays basic a
NetEngine IAD User GuideIAD Reports 228Serial (USI) Statistics ReportType S to display the Serial Statistics report. This report displays basic serial
NetEngine IAD User GuideIAD Reports 229ATM Statistics ReportThis report displays basic ATM transport statistics at the cell level for all ports and PV
NetEngine IAD User GuideIAD Reports 230OAM Tx No. of cells transmitted with CLPI (Cell Loss Priority Indication) bit is on.CLPI Tx No. of OAM (Operati
NetEngine IAD User GuideIntroduction 6Figure 1–4. 7000 Family IAD Front Panel Rear Panel ConnectorsOn the rear panel, the IAD contains several connec
NetEngine IAD User GuideIAD Reports 231G2237 xDSL Statistics Report Table 12–21.G2237 xDSL Statistics ReportParameter DescriptionOperational State Cur
NetEngine IAD User GuideIAD Reports 232H.DSL2Remote HDSL2 Version Current version of the Remote HDSL2.Remote Country Code Current Remote Country Code.
NetEngine IAD User GuideIAD Reports 233Ethernet Statistics ReportTable 12–22.Ethernet Statistics ReportParameter DescriptionReceived Packet Informatio
NetEngine IAD User GuideIAD Reports 234carrier sense lost No. of times that the carrier sense condition was lost or never asserted when attempting to
NetEngine IAD User GuideIAD Reports 235G7070 ADSL Statistics Report Table 12–23.G7070 ADSL Statistics ReportParameter DescriptionOperational Seconds T
NetEngine IAD User GuideIAD Reports 236POTS Statistics ReportTable 12–24.POTS Statistics ReportParameter DescriptionLine X Active/Inactive Current sta
NetEngine IAD User GuideIAD Reports 237BRI Statistics Report Clearing Media StatisticsTo clear network statistics, type Z on the Network Statistics me
NetEngine IAD User GuideIAD Reports 238Continue resetting network statistics, or press Escape to return to the Network Statistics menu.Route Table Rep
NetEngine IAD User GuideIAD Reports 239You must enable bridging for this table to display. For more information on enabling bridging, see Bridge Confi
NetEngine IAD User GuideIAD Reports 240Otherwise, the following information is displayed for each entry:Press any key to return to the Reports menu.Sy
NetEngine IAD User GuideIntroduction 7AC PowerConnects the IAD to an AC outlet of 108-130 volts via an AC power cord.10/100Base-T Ethernet PortConnect
NetEngine IAD User GuideIAD Reports 241Highest Memory Used 901KB (922959 Bytes)Kernel Free Memory 241KB (247016 Bytes)Free Blocks 1 BlocksLargest Free
NetEngine IAD User GuideIAD Reports 242
NetEngine IAD User GuideIntro-ductionThe command line interface is often more convenient to use than the menu interface. Many of the tasks you normall
NetEngine IAD User GuideCommand Line Interface 244on | offKeywords to enable (on) or disable (off) STP.slotNumeric value identifying the connection (0
NetEngine IAD User GuideCommand Line Interface 245Command Line Interface ReferenceEach command in the command line interface is described below, in al
NetEngine IAD User GuideCommand Line Interface 246reset systemDescription. Performs a soft system reset. reset systemDiscussion. Any time you use the
NetEngine IAD User GuideCommand Line Interface 247set bridge stp globalDescription. Enables or disables Spanning Tree Protocol globally.set bridge stp
NetEngine IAD User GuideCommand Line Interface 248set dhcp server rangeDescription. Sets the DHCP server low and high IP address range.set dhcp server
NetEngine IAD User GuideCommand Line Interface 249set lan bridgeDescription. Enables or disables bridging on a LAN port.set lan bridge <on | off>
NetEngine IAD User GuideCommand Line Interface 250set lan rip Description. Enables or disables RIP on a WAN IP port If you do not enter any optional p
NetEngine IAD User GuideIntroduction 8
NetEngine IAD User GuideCommand Line Interface 251set mgcp listening portDescription. Specifies the UDP port the Notified Entity (call agent) is liste
NetEngine IAD User GuideCommand Line Interface 252set mgcp voice connectionDescription. Specifies the slot, interface, port, and connection for the vo
NetEngine IAD User GuideCommand Line Interface 253set sdsl speedDescription. Sets the SDSL speed. This command sets the speed to manual framed (Nokia)
NetEngine IAD User GuideCommand Line Interface 254set wan atm vcDescription. Sets an ATM VC on a given WAN port—RFC 1483 and RFC 2364 VC Muxing PVCs,
NetEngine IAD User GuideCommand Line Interface 255set wan datalinkDescription. Sets the datalink protocol to Frame Relay or ATM. If you don’t enter op
NetEngine IAD User GuideCommand Line Interface 256set wan ip addressDescription. Sets the WAN IP address. If you do not enter any optional parameters,
NetEngine IAD User GuideCommand Line Interface 257set wan rip Description. Enables and disables RIP on a WAN IP port. If you do not enter any optional
NetEngine IAD User GuideCommand Line Interface 258
NetEngine IAD User GuideThis chapter describes procedures for troubleshooting and diagnosing problems that may be associated with the IAD.Diagnostics
NetEngine IAD User GuideTroubleshooting and Diagnostics 260Using the DiagnosticsMenuDiagnostic tasks are all displayed and accessed on the Diagnostics
NetEngine IAD User GuideThis chapter describes the steps to install, connect, and set the IP address of the NetEngine IAD. It introduces the menu inte
NetEngine IAD User GuideTroubleshooting and Diagnostics 261To perform a specific test, type the option and proceed to the corresponding section.Perfor
NetEngine IAD User GuideTroubleshooting and Diagnostics 262Lines 3 and 4 are connected togetherLines 5 and 6 are connected togetherLines 7 and 8 are c
NetEngine IAD User GuideTroubleshooting and Diagnostics 263—or—Type N to test a specific line. The IAD prompts you for the port number.3. The IAD prom
NetEngine IAD User GuideTroubleshooting and Diagnostics 264Performing an On/Off Hook TestThe On/Off Hook test reports the hook state of each voice por
NetEngine IAD User GuideTroubleshooting and Diagnostics 265SDSL DiagnosticsTo perform SDSL diagnostics, type S on the Diagnostics menu.The IAD display
NetEngine IAD User GuideTroubleshooting and Diagnostics 266ISDN-BRI DiagnosticsType B to perform BRI Diagnostics. The IAD displays the BRI Diagnostics
NetEngine IAD User GuideTroubleshooting and Diagnostics 267Trouble-shooting the IADThis section provides information for troubleshooting symptoms asso
NetEngine IAD User GuideTroubleshooting and Diagnostics 268Cannot receive or send dataIncorrect PVC/DLCI set for data channelVerify these settings:VPI
NetEngine IAD User GuideTroubleshooting and Diagnostics 269The table following lists the IAD provisioning parameters on the voice gateway that identif
NetEngine IAD User GuideTroubleshooting and Diagnostics 270
NetEngine IAD User GuideQuick Start Guide 10Unpacking the IADEach IAD is packed and shipped in a durable container. If you haven’t already done so, op
NetEngine IAD User GuideThis chapter describes how to verify that the NetEngine IAD operates properly after installation. It also covers maintenance a
NetEngine IAD User GuideVerification 272Power-up TestThe NetEngine IAD displays an indication of normal operation when you first power it up. When you
NetEngine IAD User GuideVerification 27311. Using a straight-through cable, connect the Ethernet LAN port on the IAD to your local LAN patch panel or
NetEngine IAD User GuideVerification 274
NetEngine IAD User GuideMenu Map This appendix provide a map of the menu interface for the NetEngine family of IADs.A. Menu MapLog OnMain MenuESC(Log
NetEngine IAD User GuideMenu Map 276P. VoicePathConfigure*J. Set Jitter DelayD. Display Jitter DelayS. Set Start Mode(Loop Start/Ground Start)T. Set
NetEngine IAD User GuideCountry Codes TablesThis appendix specifies the settings for each country code setting supported by the IAD. When you select a
NetEngine IAD User GuideCountry Codes 278Table B–3. Country Code Settings—Belgium2, Denmark, and ItalyParameters Belgium2 Denmark ItalyMin. Flash Hook
NetEngine IAD User GuideThis appendix list the specifications for the 6000 NetEngine IAD family, including the 6100, 6200, 6300 and 6500, and the 7000
NetEngine IAD User GuideNetEngine IAD Specifications 280 REN 6100-4,6204/8,6204/8c,6300-4/86108,6504/82.5 REN per port5 REN per portLoop Current 6100-
. - iii - NetEngine IAD User Guide Table of ContentsPrefaceAudience...xi
NetEngine IAD User GuideQuick Start Guide 11vertically, ensure at least 3 inches of distance between other IADs or other equipment. Wiring Requirement
NetEngine IAD User GuideNetEngine IAD Specifications 281 Table C–3. 6000 Family Digital Voice Features Feature DescriptionCompression G.711 (64 kbps
NetEngine IAD User GuideNetEngine IAD Specifications 282Table C–5. 6000 Family WAN Interface Features Feature DescriptionADSL G.lite, G.dmt—6100-4WAN
NetEngine IAD User GuideNetEngine IAD Specifications 283DSLAMs Cisco, Coppermountain, Innovia, Lucent, NokiaVoice Gateways CopperCom, JetStream; AAL2/
NetEngine IAD User GuideNetEngine IAD Specifications 284 Table C–6. 6000 Family Transport Protocol Features Feature DescriptionATMAdaption Layers AAL
NetEngine IAD User GuideNetEngine IAD Specifications 285 Table C–8. 6000 Family Security FeaturesFeature DescriptionFirewall IP Filtering (in and out
NetEngine IAD User GuideNetEngine IAD Specifications 2867000 Family The 7000 family is comprised of the NetEngine 7200 and NetEngine 7300. The IADs sh
NetEngine IAD User GuideNetEngine IAD Specifications 287 Table C–12. 7000 Family Data Features Feature DescriptionLAN Interface 10/100 BaseT Ethernet
NetEngine IAD User GuideNetEngine IAD Specifications 288Cell Delay Variation BufferConfigurable 0-30 msOAM Cell Handling F4|F5 segment and end-to-end
NetEngine IAD User GuideConnector PinoutsThis appendix specifies pinouts for each connector on the IAD. D. Connector PinoutsTable D–1. RS-232 DB-9 Co
NetEngine IAD User GuideConnector Pinouts 290Table D–4. 10BaseT Connector Pin AssignmentsPin Signal Pin Signal1Tx+ 5NC2Tx- 6Rx-3Rx+7NC4NC 8NCTable D–5
NetEngine IAD User GuideQuick Start Guide 12Power Up the IAD1. With the console cable connected, on 6000 family IADs plug the AC power adapter into th
NetEngine IAD User GuideConnector Pinouts 291Table D–8. T1/E1 Connector Pin AssignmentsPin Signal Pin Signal1Rx Ring5Tx Ring2Rx Tip6NC3NC 7NC4Tx Tip8N
NetEngine IAD User GuideConnector Pinouts 292
NetEngine IAD User GuideGlossary 10/100BaseT. 10-Mbps baseband Ethernet specification that uses two pairs of twisted-pair cabling: one pair for transm
NetEngine IAD User GuideGlossary 294IGMP. Internet Group Management Protocol. Transport layer multicasting protocol used by IP hosts to register their
NetEngine IAD User GuideGlossary 295OSI Reference Model. Network architectural model developed by ISO and ITU-T. The model consists of the following s
NetEngine IAD User GuideGlossary 296Router. Network layer device that uses one or more metrics to determine the optimal path to forward network traffi
- 2 - NetEngine IAD User GuideNumerics10/100Base-T Ethernet 4, 76000 familyfeatures of 2front panel 3generallyIADs described 2rear panel 4telephone in
- 3 - NetEngine IAD User GuideCCE mark xviiiChannel Configuration menu 74, 78Cisco 282supported DSLAM 282CODEC, testing 262command line interface refe
- 4 - NetEngine IAD User GuideEIA-530 interface for USI 21EmptyCells, configuring 92Encapsulationsetting proprietary voice 84Encapsulation, setting in
- 5 - NetEngine IAD User GuideIP filtering 169filter parameters 122filter, deleting 124filter, details 123filters, deleting by type 125filters, displa
NetEngine IAD User GuideQuick Start Guide 137. Type the default password (supervisor, or your password if different) and press Enter.8. If log in is n
- 6 - NetEngine IAD User GuideT1 Configuration 70, 72T1 Frame Mode 72TFTP Server 47Tx Clock Source (E1) 79Utilities 33Utilities (7000) 36Voice Configu
- 7 - NetEngine IAD User GuideQQuick Configuration menu 102quick configuration, using in 6300 102quit CLI command 245RRADIUS configurationdisplaying 2
- 8 - NetEngine IAD User GuideSystem Contact, configuring 30System Location, configuring 31System Name, configuring 31Trap Host IP address, configurin
- 9 - NetEngine IAD User GuideWAN setupADSL with ATM 54E1 with ATM 54E1 with Frame Relay 54G.SHDSL with ATM 55SDSL with ATM 55SDSL with ATM (6300, 730
NetEngine IAD User GuideQuick Start Guide 14Figure 2–2. Router Configuration MenuType C to select Configure Port IP Address. 3. The IAD displays the
NetEngine IAD User GuideQuick Start Guide 156. The IAD displays the following information: Type the new subnet mask (usually 255.255.255.0) and press
NetEngine IAD User GuideQuick Start Guide 16Connecting via TelnetTo manage the IAD via the LAN (or Intranet), you must set an IP address for the Ether
NetEngine IAD User GuideQuick Start Guide 174.Type your password and press Enter to display the Main menu.Using the Menu InterfaceThe NetEngine IAD pr
NetEngine IAD User GuideQuick Start Guide 18Figure 2–4. Main Menu for Supervisor Figure 2–5. Main Menu for Network Administrator Figure 2–6. Main M
NetEngine IAD User GuideQuick Start Guide 19Navigating the IAD Menu InterfaceMenus in the IAD configuration system are arranged hierarchically. That i
NetEngine IAD User GuideQuick Start Guide 20Exiting the Menu InterfaceTo exit the menu interface, return to the Main menu using the Escape key, and pr
. - iv - NetEngine IAD User GuideUsing the Menu Interface ...17Basic IAD Configuration ...
NetEngine IAD User GuideQuick Start Guide 21Making G.SHDSL ConnectionsG.SHDSL-equipped IADs use an RJ11 connector on the rear panel for WAN connection
NetEngine IAD User GuideQuick Start Guide 22Making RJ21X Connections (7000 family)The pin assignments for the RJ21X connector are telco standard. Conn
Polycom, Inc. NetEngine IAD User Guide This chapter describes how to control security to your IAD, validate users using a RADIUS server, configure SNM
NetEngine IAD User GuideAdministration 24IAD SecurityTo maintain IAD security, the IAD provides multi-level login access using a single user ID and pa
NetEngine IAD User GuideAdministration 25Table 3–2 lists the default values for the user IDs and passwords:The user ID and password may contain up to
NetEngine IAD User GuideAdministration 26Changing the User Level User IDTo change the user ID for the User security level (the only security level tha
NetEngine IAD User GuideAdministration 27RADIUS Server SettingsYou can use a RADIUS server to determine the validity of unknown user ID/password pairs
NetEngine IAD User GuideAdministration 283. Type the new encryption key and press Enter.4. Reset the IAD (page 15).Displaying the RADIUS Configuration
NetEngine IAD User GuideAdministration 29Setting Up SNMPYou can enable SNMP over IP and/or EOC (when the voice gateway is AAL2/LES CAS or ELCP). By de
NetEngine IAD User GuideAdministration 30Enabling and Disabling SNMP via IPType E to enable or disable SNMP via IP:1. The IAD displays the current sta
. - v - NetEngine IAD User GuideSelecting the Physical Interface ...60Configuring the G.SHDSL Interface...
NetEngine IAD User GuideAdministration 31Configuring the System NameType N to configure the system name (up to 39 alphanumeric characters):1. The IAD
NetEngine IAD User GuideAdministration 32Enabling or Disabling SNMP Traps via EOCType U to enable or disable SNMP traps via EOC:1. The IAD displays th
NetEngine IAD User GuideAdministration 33Upgrading the SystemPeriodically, Verilink may provide new software that you will download to the IAD to upgr
NetEngine IAD User GuideAdministration 342. Type X to display the File Transfer menu.Figure 3–4. File Transfer Menu 3. Type X to update the entire sy
NetEngine IAD User GuideAdministration 35Setting up Your LAN ConnectionThe IAD LAN port may be set for full duplex Ethernet operation if your IAD is s
NetEngine IAD User GuideAdministration 36Using System UtilitiesThe Utilities menu contains utility commands, and several menus to upgrade ACOS softwar
NetEngine IAD User GuideAdministration 37Using Trace RouteUse Trace Route to trace the network route to a specified host. To run Trace Route, follow t
NetEngine IAD User GuideAdministration 38Configuring the Console Timeout PeriodTo maintain security, you can set the amount of time a console or Telne
NetEngine IAD User GuideAdministration 392. The IAD displays the following menu:Type 1 to set the config.st config file as the boot file—or—Type 2 to
NetEngine IAD User GuideAdministration 401. Type A on the Utilities menu. The IAD deletes any existing reset reason, and displays the Utility menu.
. - vi - NetEngine IAD User GuideConfiguring DNS Client ... 114Configuring DHCP Client...
NetEngine IAD User GuideAdministration 41Using the File SystemThe File System menu contains commands to manage files on the IAD. To display the File S
NetEngine IAD User GuideAdministration 42Copying FilesTo duplicate a file with a new name, follow these steps:1. Type C on the File System menu. The I
NetEngine IAD User GuideAdministration 43Using the Debug MenuThe Debug menu contains commands to set various debugging options. Debugging should only
NetEngine IAD User GuideAdministration 44Enabling and Disabling STP Debug ModeWhen you enable STP debugging, the IAD displays STP debug messages. To e
NetEngine IAD User GuideAdministration 45Performing File TransfersThe File Transfer menu allows you to transfer groups of files to or from the IAD. To
NetEngine IAD User GuideAdministration 46Updating ACOSType O on the File Transfer menu to display the File Transfer Method menu and download Verilink’
NetEngine IAD User GuideAdministration 47Type the name of the file and press Enter. To exit without transferring the file, press Escape or Enter witho
NetEngine IAD User GuideAdministration 48Setting Derived Timing OptionsUse the Derived Timing options to enable and disable Derived Timing, and to deb
NetEngine IAD User GuideAdministration 492. Type 1, 2, or 3 to enable or disable specific derived timing debugging messages.For each option, the IAD d
NetEngine IAD User GuideAdministration 50
. - vii - NetEngine IAD User GuideSetting Jitter Delay ...142Displaying Jitter Delay...
. NetEngine IAD User Guide This chapter describes how to configure the IAD WAN interface and datalink protocol for data operation.Basic WAN setup task
NetEngine IAD User GuideWAN Configuration 52Basic WAN Setup TasksTo set up the IAD for voice and data operation, you must perform at least these basic
NetEngine IAD User GuideWAN Configuration 53Figure 4–2. T1/E1 WAN Configuration Flowchart T1/E1InterfaceSet datalinkprotocolYe sEndConfigureATM optio
NetEngine IAD User GuideWAN Configuration 54Identifying your WAN Interface and Datalink ProtocolThe sections you’ll use to perform WAN configuration d
NetEngine IAD User GuideWAN Configuration 55LAN LINK LAN ACT WAN LINK VOICEPOWER66204c6208c7216cChannelized T1 with Frame Relay1. Set the datalink pro
NetEngine IAD User GuideWAN Configuration 56Using the WAN Config-uration MenuConfiguring the IAD for data involves several tasks. Tasks in this chapte
NetEngine IAD User GuideWAN Configuration 57Selecting ATM or Frame RelayWhen you select ATM as the datalink protocol, the IAD displays the ATM and PVC
NetEngine IAD User GuideWAN Configuration 58Setting Up TDM VoiceTDM Voice allows you to set up data and voice circuits on channelized T1 circuits. You
NetEngine IAD User GuideWAN Configuration 599. The IAD asks you for the starting channel:Enter starting channel of this voice channel chunk:Type the s
NetEngine IAD User GuideWAN Configuration 60Selecting the Physical InterfaceOn all IADs except the 6500 series, the WAN interface is fixed. On 6500 IA
. - viii - NetEngine IAD User GuideDisplaying DHCP Server Assigned and Unassigned Addresses ...178Disp
NetEngine IAD User GuideWAN Configuration 61Configur-ing the G.SHDSL InterfaceThe tasks described in this section all begin on the G2237 xDSL Configur
NetEngine IAD User GuideWAN Configuration 62Selecting CPE or CO Mode1. Type 2 to display the Configure CPE/CO Mode menu.Figure 4–11. Configure CPE/CO
NetEngine IAD User GuideWAN Configuration 63Configur-ing the SDSL Interface—6500The tasks described in this section all begin on the G2237 xDSL Config
NetEngine IAD User GuideWAN Configuration 64Configuring the Adaptive Rate Mode1. Type 3 to display the SDSL Rate Mode menu.Figure 4–15. Configure SDS
NetEngine IAD User GuideWAN Configuration 65Configur-ing the SDSL InterfaceThe tasks described in this section all begin on the SDSL Configuration men
NetEngine IAD User GuideWAN Configuration 66Setting Auto Cycle—Nokia DSLAMType 2 to set the SDSL speed to Auto Cycle for connecting to a Nokia DSLAM.T
NetEngine IAD User GuideWAN Configuration 67Setting SDSL Speed for IMAS DSLAM—Nortel DSLAM1. Type 7 to set the SDSL first try speed for connecting to
NetEngine IAD User GuideWAN Configuration 682. The IAD prompts for an entry:Enter SDSL Auto Cycle Speed Entry to Configure (1..14):Type the value of t
NetEngine IAD User GuideWAN Configuration 69Configur-ing the ADSL InterfaceThe tasks described in this section all begin on the ADSL Configuration men
NetEngine IAD User GuideWAN Configuration 70Setting the Interface to T1 or E1To determine the WAN interface setting, or to switch the WAN interface fo
. - ix - NetEngine IAD User GuideDeleting a NAT Local Server Entry...200Deleting a NAT Alias Entry ...
NetEngine IAD User GuideWAN Configuration 71Switching from T1 to E1If your IAD is set for T1 and it is being deployed in an E1 environment: 1. Type 9
NetEngine IAD User GuideWAN Configuration 72Configur-ing the T1 InterfaceThe tasks described in this section all begin on the T1 Configuration menu. T
NetEngine IAD User GuideWAN Configuration 73Setting Line Build Out1. Type 2 (Select Transmit Line Build Out) to display the Line Build Out menu.Figure
NetEngine IAD User GuideWAN Configuration 74Figure 4–27. Loopback Menu Type the option number: 1, 2 or 3 to enable or disable Outward Payload, Outwar
NetEngine IAD User GuideWAN Configuration 75Enabling or Disabling Specific Channels1. Type 3 to enable or disable specific channels. If all channels a
NetEngine IAD User GuideWAN Configuration 76Displaying Physical Layer Stats and Alarm LogThe physical layer statistics displays the T1 error rate in e
NetEngine IAD User GuideWAN Configuration 77Figure 4–31. E1 Configuration menu Type the option to set the frame mode. 2. The IAD saves the configurat
NetEngine IAD User GuideWAN Configuration 78Figure 4–33. Configure S-Bits Menu 3. To toggle a given bit, type the corresponding option number.4. The
NetEngine IAD User GuideWAN Configuration 79Enabling or Disabling Specific Channels1. Type 3 to enable or disable specific channels. If all channels a
NetEngine IAD User GuideWAN Configuration 80Displaying Physical Layer Stats and Alarm Log1. Type P to display the physical layer statistics and the al
Comments to this Manuals